Professional self-priming solenoid valve aging test equipment WH-ZJ01-409. 5 independent stations with adjustable pull-in voltage (0-30V), holding voltage (0-30V), cycle count up to 999,999. Compressed air testing capability.

Description

The WH-ZJ01-409 Self-Priming Solenoid Valve Aging Test Equipment (Solenoid Valve Durability Test Bench) is designed for performance and life cycle testing of self-priming solenoid valves. The system features 5 test stations with independent controls, LED display of test parameters, and comprehensive monitoring capabilities.

Also available: WH-ZJ01-407 model for 1-3 stations with individually programmable parameters.

Product Specifications

Parameter Range / Specification
Test Cycles 0 – 999,999 times (presettable)
Action Frequency 0 – 30 cycles/min (adjustable)
Pull-in (Pick-up) Voltage 0.0V – 30.0V (adjustable)
Holding (Maintain) Voltage 0.0V – 30.0V (adjustable)
Compressed Air Pressure 0.5 kPa – 10 kPa (adjustable)

Key Features & Advantages

1. Five Independent Test Stations

  • 5 stations for simultaneous testing

  • Individual cycle counting per station

  • Independently adjustable mounting positions (left/right, forward/backward)

  • Dedicated夹具 (fixtures) for each station with compressed air connection

2. Comprehensive Control Capabilities

  • Test cycles, action frequency, and operating voltage arbitrarily adjustable per test requirements

  • LED display of all test parameters

  • Individual start/stop switch for each station

  • Master stop button to halt all tests simultaneously

3. Real-Time Monitoring & Fault Detection

  • LED indicator monitors each solenoid valve’s operating status

  • If a valve fails during testing: automatic test stop + audible/visual alarm

  • Prevents cascade failures and identifies bad samples immediately

4. Power Failure Memory

  • All set parameters (timing, test counts) saved after power loss

  • No reprogramming required after power interruption

5. Presettable Cycle Count with Auto-Stop

  • Set target cycle count

  • System automatically stops and alarms when reached

  • Countdown mode available with system lockout at completion

6. Adjustable Timing Parameters

Timing Parameter Range Description
Pull-in (Strong Attraction) Time 0 – 99.99 sec Initial high-voltage period to open valve
Holding (Maintain) Time 0 – 99.99 sec Reduced-voltage period to keep valve open
Stop (Off) Time 0 – 99.99 sec Valve closed, waiting for next cycle

7. Overcurrent Protection

  • Pull-in overcurrent alarm: 3.0A

  • Holding overcurrent alarm: 3.0A

  • Protects test equipment and valves under test

8. Compressed Air Testing Capability

  • Air pressure adjustable: 2500Pa – 4000Pa (2.5kPa – 4.0kPa)

  • Optional: 0.5kPa – 10kPa range

  • Pressure-based pass/fail detection – valve operation verified by air flow/pressure

Technical Specifications (Detailed)

Operating Environment

Parameter Condition
Power Supply AC220V ±10%, 50Hz
Operating Temperature -25°C ~ +85°C
Operating Humidity 0% – 95% RH

Test Parameters Summary

Parameter Range
Test Cycles 0 – 999,999 (presettable)
Action Frequency 0 – 30 cycles/min
Pull-in Time 0 – 99.99 sec
Holding Time 0 – 99.99 sec
Stop Time 0 – 99.99 sec
Pull-in Voltage DC 0.0V – 30.0V
Holding Voltage DC 0.0V – 30.0V
Pull-in Overcurrent Alarm 3.0A
Holding Overcurrent Alarm 3.0A
Compressed Air Pressure 2.5kPa – 4.0kPa (standard); 0.5-10kPa (optional)

Test Workflow

The WH-ZJ01-409 follows an automated test sequence:

  1. Power ON – Solenoid valve energized

  2. Pull-in phase – Strong attraction voltage applied (0-99.99 sec, LED indicator on)

  3. Holding phase – Reduced holding voltage applied (0-99.99 sec, LED indicator on)

  4. Power OFF – Valve closes

  5. Stop time – Wait period (0-99.99 sec)

  6. Air pressure detection – Verifies valve opened/closed correctly (optional)

  7. Cycle count increment – Counter advances by 1

  8. Repeat – Next cycle begins

Applications

  • Self-priming solenoid valve manufacturers – quality control & R&D

  • Gas appliance manufacturers – incoming inspection of valves

  • Water treatment equipment manufacturers – valve durability testing

  • Automotive component suppliers – solenoid valve validation

  • Third-party test laboratories – certification testing

Why Choose WH-ZJ01-409?

Feature Benefit
5 independent stations Test 5 valves simultaneously – 80% time savings
Dual voltage control (pull-in + holding) Simulates real-world solenoid operation (high inrush, low holding)
0-30V adjustable range Tests valves rated for 3V, 5V, 6V, 12V, 24V, etc.
Compressed air testing Verifies mechanical operation, not just electrical
Individual failure detection Stops only failed station – others continue testing
Power failure memory No data loss after power outage
Overcurrent protection Prevents damage to valves and test system
-25°C to +85°C operation Suitable for harsh factory environments

Reviews

There are no reviews yet.

Be the first to review “Self-Priming Solenoid Valve Aging Test Equipment | Solenoid Valve Durability Tester WH-ZJ01-409”