Description
The WH-ZJ01-409 Self-Priming Solenoid Valve Aging Test Equipment (Solenoid Valve Durability Test Bench) is designed for performance and life cycle testing of self-priming solenoid valves. The system features 5 test stations with independent controls, LED display of test parameters, and comprehensive monitoring capabilities.
Also available: WH-ZJ01-407 model for 1-3 stations with individually programmable parameters.
Product Specifications
| Parameter | Range / Specification |
|---|---|
| Test Cycles | 0 – 999,999 times (presettable) |
| Action Frequency | 0 – 30 cycles/min (adjustable) |
| Pull-in (Pick-up) Voltage | 0.0V – 30.0V (adjustable) |
| Holding (Maintain) Voltage | 0.0V – 30.0V (adjustable) |
| Compressed Air Pressure | 0.5 kPa – 10 kPa (adjustable) |
Key Features & Advantages
1. Five Independent Test Stations
-
5 stations for simultaneous testing
-
Individual cycle counting per station
-
Independently adjustable mounting positions (left/right, forward/backward)
-
Dedicated夹具 (fixtures) for each station with compressed air connection
2. Comprehensive Control Capabilities
-
Test cycles, action frequency, and operating voltage arbitrarily adjustable per test requirements
-
LED display of all test parameters
-
Individual start/stop switch for each station
-
Master stop button to halt all tests simultaneously
3. Real-Time Monitoring & Fault Detection
-
LED indicator monitors each solenoid valve’s operating status
-
If a valve fails during testing: automatic test stop + audible/visual alarm
-
Prevents cascade failures and identifies bad samples immediately
4. Power Failure Memory
-
All set parameters (timing, test counts) saved after power loss
-
No reprogramming required after power interruption
5. Presettable Cycle Count with Auto-Stop
-
Set target cycle count
-
System automatically stops and alarms when reached
-
Countdown mode available with system lockout at completion
6. Adjustable Timing Parameters
| Timing Parameter | Range | Description |
|---|---|---|
| Pull-in (Strong Attraction) Time | 0 – 99.99 sec | Initial high-voltage period to open valve |
| Holding (Maintain) Time | 0 – 99.99 sec | Reduced-voltage period to keep valve open |
| Stop (Off) Time | 0 – 99.99 sec | Valve closed, waiting for next cycle |
7. Overcurrent Protection
-
Pull-in overcurrent alarm: 3.0A
-
Holding overcurrent alarm: 3.0A
-
Protects test equipment and valves under test
8. Compressed Air Testing Capability
-
Air pressure adjustable: 2500Pa – 4000Pa (2.5kPa – 4.0kPa)
-
Optional: 0.5kPa – 10kPa range
-
Pressure-based pass/fail detection – valve operation verified by air flow/pressure
Technical Specifications (Detailed)
Operating Environment
| Parameter | Condition |
|---|---|
| Power Supply | AC220V ±10%, 50Hz |
| Operating Temperature | -25°C ~ +85°C |
| Operating Humidity | 0% – 95% RH |
Test Parameters Summary
| Parameter | Range |
|---|---|
| Test Cycles | 0 – 999,999 (presettable) |
| Action Frequency | 0 – 30 cycles/min |
| Pull-in Time | 0 – 99.99 sec |
| Holding Time | 0 – 99.99 sec |
| Stop Time | 0 – 99.99 sec |
| Pull-in Voltage | DC 0.0V – 30.0V |
| Holding Voltage | DC 0.0V – 30.0V |
| Pull-in Overcurrent Alarm | 3.0A |
| Holding Overcurrent Alarm | 3.0A |
| Compressed Air Pressure | 2.5kPa – 4.0kPa (standard); 0.5-10kPa (optional) |
Test Workflow
The WH-ZJ01-409 follows an automated test sequence:
-
Power ON – Solenoid valve energized
-
Pull-in phase – Strong attraction voltage applied (0-99.99 sec, LED indicator on)
-
Holding phase – Reduced holding voltage applied (0-99.99 sec, LED indicator on)
-
Power OFF – Valve closes
-
Stop time – Wait period (0-99.99 sec)
-
Air pressure detection – Verifies valve opened/closed correctly (optional)
-
Cycle count increment – Counter advances by 1
-
Repeat – Next cycle begins
Applications
-
Self-priming solenoid valve manufacturers – quality control & R&D
-
Gas appliance manufacturers – incoming inspection of valves
-
Water treatment equipment manufacturers – valve durability testing
-
Automotive component suppliers – solenoid valve validation
-
Third-party test laboratories – certification testing
Why Choose WH-ZJ01-409?
| Feature | Benefit |
|---|---|
| 5 independent stations | Test 5 valves simultaneously – 80% time savings |
| Dual voltage control (pull-in + holding) | Simulates real-world solenoid operation (high inrush, low holding) |
| 0-30V adjustable range | Tests valves rated for 3V, 5V, 6V, 12V, 24V, etc. |
| Compressed air testing | Verifies mechanical operation, not just electrical |
| Individual failure detection | Stops only failed station – others continue testing |
| Power failure memory | No data loss after power outage |
| Overcurrent protection | Prevents damage to valves and test system |
| -25°C to +85°C operation | Suitable for harsh factory environments |






Reviews