Air Pressure Switch Aging Test Equipment | Pressure Switch Life Cycle Tester

Professional air pressure switch aging test equipment WH-RS01-211 for gas appliances. Tests 5 independent stations with pressure range -250Pa to +250Pa. Programmable cycles up to 999,999 with 4 alarm setpoints

Description

The WH-RS01-211 Air Pressure Switch Aging Test Equipment is specifically designed for life cycle testing of various models of air pressure switches used in gas appliances. The system features simple, clear operation that easily meets user requirements.

Important: For operator safety and proper use of this equipment, please read the complete product manual before operation.

Operating Conditions

Parameter Condition
Power Supply AC 220V
Operating Temperature 5°C ~ 45°C
Operating Humidity 20% ~ 90% RH
Pressure Output Range -250 Pa ~ +250 Pa

Key Features & Configuration

1. Multi-Station Design

  • 5 independent test stations – each with separate start/stop switch

  • Allows simultaneous testing of multiple pressure switch samples

2. Adjustable Interval Timing

  • Interval time: 0 ~ 99.99 seconds (adjustable)

  • Simulates different duty cycles and switching frequencies

3. Dual Counter System

  • Master counter: 0 ~ 999,999 cycles (overall counting)

    • Can be set to countdown mode

    • Audible/visual alarm and lockout when preset count reached

  • Individual station counters: 0 ~ 999,999 cycles (independent counting per station)

4. Power Failure Memory

  • All set parameters (time settings and test counts) are saved after power loss

  • No need to reprogram after power interruption

5. Flexible Control Options

  • Press stop button to halt all tests simultaneously

  • Turn individual station start/stop switch to “OFF” to stop a single station

6. Four Programmable Alarm Setpoints

  • Upper positive pressure limit

  • Lower positive pressure limit

  • Upper negative pressure limit

  • Lower negative pressure limit

7. Countdown Mode & Lockout

  • When master counter is set to countdown mode and target count is reached:

    • Continuous alarm sounds

    • System locks out

    • Press “Reset” button on master counter to unlock

Technical Specifications Summary

Specification Detail
Model WH-RS01-211
Test Stations 5 (independent)
Pressure Range -250 Pa to +250 Pa
Interval Time 0 – 99.99 sec (adjustable)
Max Cycle Count 999,999
Power Supply AC 220V
Operating Temp 5°C – 45°C
Operating Humidity 20% – 90% RH
Memory Power failure retention
Alarms 4 programmable setpoints

Applications

  • Gas appliance manufacturers (water heaters, wall-hung boilers, furnaces)

  • Air pressure switch suppliers – quality control and R&D

  • Third-party test laboratories – certification testing

  • Incoming inspection departments – verifying switch reliability

Why Choose WH-RS01-211?

Feature Benefit
5 independent stations Test 5 switches simultaneously – 80% time savings vs. single station
±250 Pa pressure range Covers most gas appliance air pressure switch requirements
Dual counter system Track overall test progress and individual station performance
Power failure memory No lost data or reprogramming after power outage
4 alarm setpoints Real-time monitoring of pressure deviations
Simple operation Minimal training required for technicians

Reviews

There are no reviews yet.

Be the first to review “Air Pressure Switch Aging Test Equipment | Pressure Switch Life Cycle Tester”