+86 186 1287 7376 277167827@QQ.com Mon–Sat 8:30–17:30 (GMT+8)
中文版
Home › Products › Range hood air volume and energy efficiency testing equipment testing platform

Range hood air volume and energy efficiency testing equipment testing platform

WH-YJ01-100A

OriginZhongshan, Guangdong, China
Accuracy±0.5% F.S. class
StandardsGB-compliant systems

Technical specification

Range hood air volume and energy efficiency testing equipment
1、 Product Introduction
This equipment is an air volume testing system developed and manufactured according to the IEC61591 standard using advanced Japanese technology. Colleagues have installed a range hood air performance testing device in accordance with Appendix C of the GB/T17713-2011 "Range Hood" standard, which is an external exhaust range hood air performance testing device. It can measure the corresponding curves of static pressure and air volume, air volume and speed, current, power, efficiency, etc. It is also possible to test the sample in both inhalation and discharge states. It has the characteristics of convenience, speed, stability, reliability, and good reproducibility, and is suitable for testing and use in scientific research and production processes of related products.
Reference standard: GB/T17713-2011 Range Hood;
IEC61591 standard;
Wind box type air volume testing system
2、 Test items
1. Measurement of air volume, air pressure, and efficiency;
2. Air performance characteristic curve (curve of outlet static pressure and air volume);
3. Characteristic curve of total pressure efficiency (curve of efficiency and air volume);
4. Static pressure at specified air volume;
5. Static pressure;
6. Air volume;
7. The total pressure efficiency at the specified air volume;
8. The input power of the main motor at the specified air volume;
9. Can calculate new and old national standard values.
3、 Instrument
1. Air volume: (m3/h) 3-1200 ± 1.5% 2;
2. Static pressure/differential pressure: 0-1000Pa ± 0.25%;
3. Temperature: (℃) 0-65 ± 0.5;
4. Atmospheric pressure: 80-1100 ± 0.15%;
5. Voltage: (V) 0-240 ± 0.5%;
6. Current: (A) 0-5 ± 0.5%;
7. Power: (W) 0-1100 ± 1.0%;
8. Frequency: Hz50/60 ± 0.5.

Parameters listed are from published data — request the full specification sheet for your project.