Description
Dual station gas wall mounted boiler life test equipment
1. Product Introduction:
This equipment is designed according to the standard GB6932-2015 Household Gas Rapid Water Heater and the energy efficiency standard GB2665-2015 Household Gas Rapid Water Heater and Gas Heating Furnace Energy Efficiency Limit Values and Energy Efficiency Grades, mainly for aging tests of water heaters or heating furnaces. This device is controlled by a computer and PLC, assembled with high-quality components, and has the advantages of stable performance, safety, and reliability.
2. Technical parameters:
Number Project Parameters
1. Compressed air pressure 0.5-0.8MPa
Inlet pressure 0-1.6 MPa, 0.5% F.S
3. Outlet temperature: 0-100 ° C, 0.5% F.S
Gas flow meter pressure 0-10KPa, 0.5% F.S
Gas pressure 0-10KPa, 0.5% F.S
3. Test items:
Number inspection item parameters
1. Water outlet temperature detection 0-100 ° C
2 Bathroom Aging Test 1-30L/min
3 Heating aging test 1-40L/min
4. The inlet pressure can be adjusted from 0-1.6 MPa
Adjustable water flow rate of 0.05MPa/0.50MPa
Gas pressure adjustable from 0-10KPa
7 with leakage protection function






Reviews